Product Identification

Product ID:MACHINE CLEANER, 088
MSDS Date:09/08/1987
FSC:9150
NIIN:00N016207
MSDS Number: BLZJP

Responsible Party
DBA PRODUCTS CO INC
22 SKOKIE HIGHWAY
LAKE BLUFF, IL 60044
US

Emergency Phone: 312-234-8100

Info Phone: 312-234-8100

Cage: 60443

Contractor
DBA PRODUCTS CO INC
LAKE BLUFF, IL 60044 US

Telephone: (708) 234-8100

Cage: 60443

Ingredients

ETHYLENE, TRICHLORO- (MFR CAS# 79-00-6)

CAS: 79-01-6

RTECS: KX4550000

Fraction By Weight: 10%

OSHA PEL 100 PPM/100 STEL

ACGIH TLV: 50 PPM/100,A5STEL;93

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS


ETHYLENE GLYCOL (POLY SOL EE)

CAS: 107-21-1

RTECS: KW2975000

Fraction By Weight: <20%

OSHA PEL 50 PPM C

ACGIH TLV: 50 PPM C

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


POLY SOL EB

CAS: 177-21-1

Fraction By Weight: <20%


NEAPHTALENE (APCO SOLVENT #140)

CAS: 91-20-3

RTECS: QJ0525000

Fraction By Weight: <40%

OSHA PEL 10 PPM;15 PPM STEL

ACGIH TLV: 10 PPM;15 PPM STEL

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS


BY DIKING/IMPOUNDING. ADVISE AUTH IF PROD HAS

RTECS: 9999999ZZ


NO SMOKING IN AREA OF USE. DO NOT USE IN GEN

RTECS: 9999999ZZ


HEAT AND/OR UV REDIATION MAY CAUSE THE FORMATION OF

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL OF HIGH VAP CONC MAY HAVE
RESULTS RANGING FROM DIZZINESS, HEADACHE & RESP IRRIT TO
UNCONSCIOUSNESS. PRLNG OR RPTD LIQ CONT W/SKIN WILL DRY & DEFAT
SKIN, LEADING TO IRRIT & DERM. HEALTH STUDIES H AVE SHOWN THAT MANY
PETROLEUM HYDROCARBONS POSE POTENTIAL HUMAN HEALTH RISKS WHICH MAY
VARY FROM (EFTS OF OVEREXPOS).
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HEALTH HAZ:PERSON TO PERSON. AS A PRECAUTION,
EXPOSURE TO LIQUID AND VAPORS OF PETROLEUM PRODUCT SHOULD BE
MINIMZED.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INGEST:DO NOT INDUCE VOM;CALL HOSPITAL EMER ROOM/MD IMMED.
INHAL: REMOVE TO FRESH AIR IMMED. IF BRTHG STOPS, GIVE ARTF RESP.
KEEP WARM & QUIET. GET MD IMMED. EYE:FLUSH W/LG AMT OF H*20,
LIFTING UPPER & LOWER LIDS OCCASNLY. CONTINUE FOR AT LEAST 15 MIN.
GET MD IMMED. SKIN:REMOVE CONTAM CLTHG. WASH AFFECTED AREA W/SOAP &
H*20. GET MD IF IRRIT PERSIST. AN EMOLLIENT CREAM OR LOTION IS
BENEFICIAL.

Fire Fighting

Flash Point Method:TCC
Flash Point:120F,49C
Extinguishing Media:CARBON DIOXIDE, ALL PURPOSE DRY CHEMICAL, ALCOHOL
FOAM, POLYMER FOAM.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD PRESS DEMAND SCBA &
FULL PROT EQUIP . WATER MAY BE INEFT, BUT MAY BE USED TO COOL EXPOS
CNTNR TO PVNT PRESS BUILD-UP & (SUPP DATA).
Unusual Fire/Explosion Hazard:VAP ACCUM WOULD FLASH IF IGNITED. DO NOT
MIX/STORE W/STRONG OXIDANT SUCH AS LIQ CHLORINE OR CONC OXYGEN.
"EMPTY" CNTR RETAIN PROD RESIDUE. (SEE SUPP DATA).

Accidental Release

Spill Release Procedures:REMOVE ALL POSS IGNITION SOURCE. AVOID BRTHG
VAP, KEEP PEOPLE AWAY. RECOVER FREE LIQ. ADD ABSORB (SAND, EARTH,
SAWDUST/VERMICULITE), TO SPILL AREA. VENT CONFINED SPACES. OPEN ALL
WINDOWS & DOORS. KEEP PETROLEUM PROD OUT OF SEWER & (SEE SUPP
DATA).
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT STORE ABOVE 120 F. STORE LARGE
QUANTITY IN COMPLIANCE WITH OSHA 29 CFR 1910.106.
Other Precautions:DO NOT TAKE INTERNALLY. CLOSE CONTAINER AFTER EACH
USE. EMPTY CONTAINERS MUST NOT BE WASHED AND RE-USED FOR ANY
PURPOSE. DO NOT WELD, BRAZE OR CUT ON EMPTY CONTAINER. NEVER USE
PRESSURE TO EMPTY. DRUM IS NOT A PRESSURIZED VESSEL.

Exposure Controls

Respiratory Protection:IN RESTRICTED VENTILATION AREA USE
SELF-CONTAINED BREATHING APPARATUS TO REMOVE ORGANIC VAP. REFER TO
OSHA 29 CFR 1910-134 "RESPIRATORY PROTECTION".
Ventilation:MECHANICAL SUFFICIENT TO MAINT WORKPLACE CONCENTRATION
BELOW TLV.
Protective Gloves:PROT GLOVES POLYETHYLENE, NEOPRENE.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:WEAR PROTECTIVE CLOTHING.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRE FIGHTING PROC:POSS AUTO-IGNIT/EXPLO WHEN EXPO TO EXTREME HEAT. IF
H*20 IS USED, FOG NOZZ ARE PERFERABLE. UNUSUAL FIRE:DO NOT
PRESSURIZE, CUT, HEAT, WELD/EXPO SUCH CNTNR TO FLAME; THEY MAY
EXPLODE & CAUSE INJURY/DEATH. THERM DECOMP PROD MAY INCLUDE HCL
AND PHOSGENE . SPILL RELEASE:WATERCOURSES (SEE ING 5) .

Chemical Properties

HCC:F4
Boiling Pt:B.P. Text:165F,74C
Vapor Density:>THAN AIR
Evaporation Rate & Reference:< THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:100%

Stability

Stability Indicator/Materials to Avoid:YES
AVOID STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:EXCESSIVE HEAT AND SOURCE OF IGNITION.
Hazardous Decomposition Products:CARBON MONOXIDE IF BURNED WITH
INSUFFICIENT AIR. HCL, PHOSGENE .
Conditions to Avoid Polymerization:KEEP AWAY FROM HEAT SPARKS AND OPEN
FLAME.

Disposal

Waste Disposal Methods:CONT FED, STATE & LOCAL AGENCY TO INSURE
COMPLIANCE DISP METHOD W/CURRENT REGS. DISP OF ABSORBED MATL AT AN
APPRVD DISP SITE/FACILITY. OBSERVE PREC FOR VOLATILE, COMBUST VAP
FROM ABSORBED MATL. DISP O F ONLY IN ACCD W/FED, STATE AND LOCAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.